Psychrometric Science in Restoration

Temperature-humidity relationships, grain depression, and the drying equation

≥4.5 mmHgVP Differential
30-50%Target RH
8-12%Timber MC Target
ASHRAEStandard

Psychrometric Science in Restoration

Psychrometric science measures the relationship between temperature, humidity, and dew point to control structural drying in disaster restoration[10]. Professional restorers use psychrometric charts to calculate the grain depression (difference between ambient humidity and target humidity) needed for effective evaporation. The IICRC S500 standard requires maintaining a vapour pressure differential of at least 4.5 mmHg[10] across wet materials to achieve efficient drying within Australian climate conditions.

Technical Standards & Science

Psychrometrics is the scientific foundation of all professional structural drying. It is the discipline that separates qualified restorers from unqualified ones — and the reason why professional drying succeeds where DIY attempts fail.

Core Psychrometric Concepts

  • Relative Humidity (RH) — The percentage of water vapour in air relative to the maximum it can hold at that temperature. RH = (Actual vapour pressure / Saturation vapour pressure) × 100%. Target indoor RH: 30–50%.
  • Dew Point — The temperature at which air becomes saturated and condensation occurs. Td ≈ T − ((100 − RH) / 5). Condensation on building surfaces causes secondary water damage.
  • Grains Per Pound (GPP) — The absolute measure of moisture in air. One pound of air can hold varying amounts of water vapour depending on temperature. GPP is temperature-independent, making it the professional's preferred metric.
  • Grain Depression — The difference between ambient GPP and the dehumidifier's outlet GPP. Higher grain depression = faster drying.
  • Specific Humidity — Mass of water vapour per unit mass of dry air. Used in engineering calculations for HVAC and drying system design.
Why Temperature Matters for DryingWarmer air holds more moisture (higher saturation capacity). Raising the temperature in a drying chamber from 20°C to 30°C nearly doubles the air's moisture-carrying capacity. Professional restorers use this principle by combining heated air movers with dehumidification to dramatically accelerate drying rates.

The Drying Equation

Evaporation Rate = (Vapour Pressure Differential × Air Flow) / Material Resistance

This equation drives every decision in professional structural drying. To maximise evaporation, restorers optimise three variables:

  • Vapour pressure differential — Increased by dehumidification (lowering air RH below material RH)
  • Air flow — Increased by air movers positioned to create laminar flow across wet surfaces
  • Material resistance — Varies by material type. Hardwood resists moisture release more than carpet

Legal & Insurance Framework

Documentation Requirements

Insurance companies increasingly require psychrometric documentation to support drying claims. Daily moisture readings, psychrometric calculations, and equipment logs demonstrate that professional standards were followed. Without this documentation, insurers may dispute the duration and cost of drying operations.

Industry Standard of CareThe IICRC S500 standard establishes the industry standard of care for structural drying. Restorers who fail to follow psychrometric drying principles may be liable for consequential damage (e.g., mould growth from inadequate drying). This standard is referenced in insurance disputes and legal proceedings.

Building Standards Compliance

The National Construction Code (NCC) and Australian Standards (AS 1684 for timber framing) specify acceptable moisture content for building materials. Timber framing must be dried to 8–12% moisture content before any enclosure work (plastering, painting). Failing to meet these thresholds before closing walls creates conditions for timber rot and mould.

Why Choose a Vetted Contractor?

Structural Drying: Vetted vs Unvetted Contractors

NRPG-Vetted Contractor
  • Psychrometric-trained technicians with daily monitoring
  • Calibrated moisture meters and thermal hygrometers
  • Documented drying curves showing daily progress
  • Equipment matched to drying class (LGR, desiccant, or conventional)
  • Drying to Australian building standard moisture thresholds
  • Complete moisture map at start and verified dry at completion
Unvetted Contractor
  • No psychrometric knowledge — drying by guesswork
  • No calibrated instruments — relies on "touch test"
  • No documentation — cannot prove drying was adequate
  • Wrong equipment for the job — extends drying time and cost
  • May declare "dry" with moisture still trapped in structure
  • No moisture verification — hidden moisture causes mould later

Frequently Asked Questions

What is psychrometrics in restoration?

Psychrometrics is the science of air-moisture relationships. In restoration, it is used to calculate optimal drying conditions by measuring temperature, relative humidity, dew point, and grains per pound of moisture in the air. Professional restorers use psychrometric charts and instruments to monitor and control the drying process scientifically.

Why does structural drying take so long?

Structural drying time depends on the drying class, material types, and environmental conditions. Concrete and hardwood release moisture much slower than carpet or drywall. The drying process must be controlled to prevent cracking, warping, and secondary damage. Rushing drying with excessive heat can damage materials. Typical structural drying takes 3–7 days for standard materials.

What equipment is used for professional drying?

Professional drying uses: Low Grain Refrigerant (LGR) dehumidifiers for most conditions, desiccant dehumidifiers for low-temperature or specialty drying, centrifugal air movers for surface evaporation, axial fans for large-area air circulation, and thermal hygrometers and moisture meters for daily monitoring.

What is the ideal humidity for drying a building?

The target relative humidity for effective structural drying is typically 30–40%, which creates sufficient vapour pressure differential to drive moisture from wet materials into the air. The IICRC recommends maintaining at least 4.5 mmHg vapour pressure differential across wet surfaces. Conditions vary by climate zone — tropical Queensland requires different parameters than temperate Melbourne.

How do you know when a building is fully dry?

A building is considered dry when moisture meter readings in all affected materials return to normal equilibrium moisture content (EMC). For timber, this is 8–12% in most Australian climates. Multiple measurement points are checked with both pin-type and pinless meters. Drying is documented with final moisture maps confirming all areas meet standard.